{"product_id":"contec-12-lead-48-hour-ecg-holter-monitor-tlc-6000","title":"Contec 12-Lead 48-Hour ECG Holter Monitor - TLC-6000","description":"\u003ch3 dir=\"ltr\"\u003eProduct Description\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThe CONTEC TLC-6000 is a compact, lightweight 12-lead traditional Holter monitoring system that integrates an ambulatory ECG recorder with advanced PC analysis software. The unit continuously captures and synchronizes standard 12-lead ECG data for up to 48 hours. Once data is captured, it is transferred via USB to PC software, where sophisticated analytical tools identify and categorize various cardiac waveforms, pacemakers, and abnormalities.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cb\u003e12-Lead Synchronous Data:\u003c\/b\u003e Collects standard 12-lead ECG waveforms simultaneously, boosting the precision of QRS searching.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cb\u003eTemplate-Based Waveform Mapping:\u003c\/b\u003e Includes more than 10 built-in diagnostic templates (such as atrial premature beat, ventricular premature beat, long interval, atrial flutter, and atrial fibrillation modules) alongside user-defined modules to spot almost any pathologic waveform.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cb\u003eAdvanced Atrial Fibrillation (AFIB) Analysis:\u003c\/b\u003e Allows physicians to use full or segmented automatic\/manual analysis to quickly isolate and assess AFIB episodes.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cb\u003eComprehensive Pacemaker Support:\u003c\/b\u003e Features deep diagnostic mapping for multiple pacemaker types (including AAI, VVI, and DDD systems).\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cb\u003eOne-Stop Report Printing:\u003c\/b\u003e Streamlines clinical workflows with a convenient \"one-key print\" feature to output medical-grade charts effortlessly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e \u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eProduct Highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cb\u003eRisk Prediction Metrics:\u003c\/b\u003e Built-in \"Heart Rate Turbulence\" (HRT) analysis to predict the death risk in patients with a history of myocardial infarction, as well as \"T-Wave Alternans\" (TWA) to flag malignant arrhythmia risks.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cb\u003eMulti-Dimensional Reporting:\u003c\/b\u003e The software incorporates advanced analytical components including Vectorcardiogram (VCG), Ventricular Late Potential (VLP), Time Vectorcardiogram (TVCG), and QT Dispersion (QTD).\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cb\u003eHeart Rate Variability (HRV):\u003c\/b\u003e Analyzes heart rate fluctuations across both short-range (5-minute) and long-range (1-hour or full-duration) windows.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTechnical Specifications :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp dir=\"ltr\"\u003eParameter\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp dir=\"ltr\"\u003eSpecification\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003eLeads\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003eStandard 12-lead\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003eRecording Duration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003eUp to 48 Hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003ePower Supply\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003eOne \"AAA\" battery or 1x \"AA\" battery (depending on specific regional battery casing revision)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003eDisplay\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003eLED \/ 0.96\" OLED Display Screen\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003eData Storage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003eHigh-capacity Flash storage \/ SD Card\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003eCalibration Voltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e1mV ±5%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003eNoise Level\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003eLess than or equal to 30µV p-p\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003eCMRR (Common Mode Rejection Ratio)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003eGreater than or equal to 60dB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003eFrequency Response\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e0.5Hz to 55Hz (-3dB) with 10Hz as benchmark\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003eLow-frequency Characteristics\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003eTime constant greater than or equal to 3.2s\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003ePolarizing Voltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e±300mV; Sensitivity: less than or equal to ±10%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003eMinimum Measure Signal\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e50 µV p-p\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003eDimensions \u0026amp; Weight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e80.5mm(L) × 59.5mm(W) × 22mm(H); Approx. 61.5g (without batteries)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp dir=\"ltr\"\u003e \u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eUse Cases\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cb\u003eAmbulatory Cardiac Diagnosis:\u003c\/b\u003e Tracking transient or intermittent symptoms like palpitations, syncope (fainting), or unexplained dizziness.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cb\u003eArrhythmia Screening:\u003c\/b\u003e Evaluating high-risk patients for hidden conditions like Atrial Fibrillation or fluttering that a resting 10-second ECG might miss.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cb\u003ePost-Myocardial Infarction Management:\u003c\/b\u003e Tracking heart rate turbulence and recovery windows following a heart attack.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cb\u003ePacemaker Optimization:\u003c\/b\u003e Assessing whether implanted pacing systems are correctly firing and capturing across standard life settings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e \u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eIn the Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\"\u003e1 × CONTEC TLC6000 Holter Recorder Unit\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e1 × 12-Lead ECG Patient Cable (1 set)\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e1 × Bag of ECG Electrodes\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e1 × USB Data Transfer Cable\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e1 × PC Software CD\/Download Authorization (with Index Code on the packaging)\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e1 × Protective Black Carry Bag with Patient Straps\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e1 × Official User Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e \u003c\/p\u003e","brand":"KDS Enterprise","offers":[{"title":"Default Title","offer_id":47974141853914,"sku":"19095","price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/7498\/2874\/files\/ContecTLC6000HolterECGsystem_12Lead_1__original.webp?v=1781853588","url":"https:\/\/kaaryamedical.com\/products\/contec-12-lead-48-hour-ecg-holter-monitor-tlc-6000","provider":"KDS Enterprise","version":"1.0","type":"link"}