{"product_id":"cms-5100-a-3para-monitor-1","title":"CMS-5100 A 3PARA  MONITOR","description":"\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eContec CMS 5100\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003emeasures NIBP, Spo2 and PR, and it is a vital sign monitor. It is applicable for adult, pediatric and neonatal for all-round monitoring. Due to its compact size, this Contec vital sign monitor is easy to carrying and suitable for indoor and outdoor monitoring.\u003c\/p\u003e\n\u003cp\u003eContec CMS 5100 patient monitor is having 2.8”  TFT\/ LCD screen with real-time data and waveform. It can simultaneously display full monitoring parameters. Contec CMS 5100 can monitor and display SpO2, PR, NIBP parameters. Contec CMS 5100 patient monitor’s rechargeable internal battery brings a lot of convenience for patient monitoring.\u003c\/p\u003e\n\u003ch3\u003eKey Features of Contec Vital Sign Monitor, CMS 5100 :\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBe applicable for adult, pediatric and neonatal for all-round monitoring\u003c\/li\u003e\n\u003cli\u003eEasy operation\u003c\/li\u003e\n\u003cli\u003eBe applicable for medicine, surgery, operating room, ICU\/CCU, emergency room, obstetrics and gynecology, pediatrics.\u003c\/li\u003e\n\u003cli\u003eBuilt-in rechargeable Li-polymer battery for uninterrupted monitoring.\u003c\/li\u003e\n\u003cli\u003eCompact and flexible appearance, easy for carrying and be suitable for indoor and outdoor(in ambulance) monitoring.\u003c\/li\u003e\n\u003cli\u003eWith user-friendly interface.\u003c\/li\u003e\n\u003cli\u003eDisplay with 2.8” (320×240) color TFT LCD and red and yellow highlight LED.\u003c\/li\u003e\n\u003cli\u003eVisual and audible alarm for Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR), and upper and lower limit of alarm can be set.\u003c\/li\u003e\n\u003cli\u003eUnique Flash memory, storage for up to 2000 NIBP data and, 30000 SpO2 data.\u003c\/li\u003e\n\u003cli\u003eConvenient and quick in inquiring measurement data, review for NIBP trend graph within 24-hour and SpO2 and Pulse rate(PR)\u003c\/li\u003e\n\u003cli\u003e Trend graph within 20-hour.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications of contec CMS 5100 patient monitor:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProduct Name\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eContec CMS5100 Vital Sign Patient monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eModel \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eCMS 5100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBrand \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eContec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eScreen\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8-inch LCD Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eStandard Parameters\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eNIBP, Spo2 and PR, Temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eStorage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eStorage for up to 2000 NIBP data and, 30000 SpO2 data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190(L)×162(W)×240(H)mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSuitable Patient Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eadult, pediatric and neonatal patient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eAlarms\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVisual and audible alarm\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efor Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR), and upper and lower limit of alarm can be set.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBattery\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e Rechargeable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eIn the Box\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eContec patient monitor CMS 5100, A SpO2 probe, An adult NIBP cuff, An extending tube for blood pressure, \u003cspan\u003eA power cord, A power adapter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003eMore details of about parameters of Contec CMS5100 patient Monitor :\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. NIBP monitoring\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement method: Oscillometry\u003c\/li\u003e\n\u003cli\u003eMeasurement mode: manual\/auto\/continuous.\u003c\/li\u003e\n\u003cli\u003eAuto measurement interval: adjustable from 1 to 90 minutes.\u003c\/li\u003e\n\u003cli\u003eResolution: 1mmHg.\u003c\/li\u003e\n\u003cli\u003eAccuracy: Maximum Mean deviation≤±5mmHg, Maximum Standard deviation≤8mmHg.\u003c\/li\u003e\n\u003cli\u003eSelf-check function.\u003c\/li\u003e\n\u003cli\u003eOverpressure protection: double protection for software and hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003ePressure Range :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eFor Adult:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystolic pressure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e40mmHg~270mmHg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMean pressure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20mmHg~235mmHg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiastolic Pressure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10mmHg~215mmHg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor Pediatric:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystolic pressure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e40mmHg~200mmHg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMean pressure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20mmHg~165mmHg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiastolic Pressure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10mmHg~150mmHg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor Neonatal:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystolic pressure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e40mmHg~135mmHg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMean pressure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20mmHg~110mmHg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiastolic Pressure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10mmHg~100mmHg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003e2. SpO2 monitoring\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous real-time measuring.\u003c\/li\u003e\n\u003cli\u003eAdopt digital SpO2 technology, which has strong anti-interference capability.\u003c\/li\u003e\n\u003cli\u003eReal-time display SpO2, pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph.\u003c\/li\u003e\n\u003cli\u003eStandard finger-clip probe for adult , binding probe for neonatal is optional.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpO2 Measuring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e35%~100% (Resolution: 1%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±2% in stage of 70%-100%, and unspecified in stage of less than 70%.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePulse Rate Measuring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e30bpm~250bpm(Resolution: 1bpm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±2bpm or ±2%, whichever is greater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Performance in Weak Filling Condition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance to surrounding light:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"KDS Enterprise","offers":[{"title":"Default Title","offer_id":47974097551578,"sku":"7491","price":12200.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/7498\/2874\/files\/CMS_5100_patient_monitor.png?v=1781173342","url":"https:\/\/kaaryamedical.com\/products\/cms-5100-a-3para-monitor-1","provider":"KDS Enterprise","version":"1.0","type":"link"}